Opens in a new tab

Heat Pumps

High-Temperature Monoblock R290

TF09
TF12
TF15
TF18
Environmentally friendly R290 refrigerant with low global warming potential for more efficient and more sustainable heat pump operation.
R290
refrigerant
3
GWP
Wi-Fi
control

ThermoFLUX DC inverter heat pumps use R290 refrigerant with an exceptionally low global warming potential (GWP) of just 3. As an environmentally friendly solution, R290 is ideal for high-temperature heating applications and operation in cold regions. Fast and simple installation allows the heat pump to be set up in a single day — on the floor, wall or roof.

Features

Technology of the future

— 01

Eco-Friendly R290

Refrigerant with GWP of only 3 — up to 700 times lower environmental impact than traditional refrigerants.
— 02

Water temperature

The maximum flow-line water temperature reaches up to 75 °C, enabling use in high-temperature heating systems as well.
— 03

Wi-Fi control

Control the device via app and enjoy online support no matter where you are.
— 04

Panasonic Compressor

Rotary compressor that operates at low frequency after reaching desired temperature, reducing consumption.
— 05

Grundfos pump

High-quality Grundfos circulation pump for reliable and efficient heat distribution.
— 06

Flexible installation

Installation in just one day — on floor, wall, or roof, without complications.

Advantages

Other features

Premium components from world-leading manufacturers for maximum reliability and efficiency.
  • R290 refrigerant with GWP 3
  • Maximum water temperature up to 75 °C
  • Two-stage rotary compressor with EVI technology
  • DC inverter brushless fans
  • Integrated circulation pump
  • Smart defrosting
  • Wi-Fi control via smartphone
  • Single-phase and three-phase connection
  • Floor, wall or roof mounting

Technical details

Detailed overview of specifications for all models
TF09 R290 T 220V TF12 R290 T 220V TF15 R290 T 220V TF18 R290 T 220V TF15 R290 T 400V TF18 R290 T 400V
Power supply V/Hz/Ph 220-240/50/1 220-240/50/1 220-240/50/1 220-240/50/1 380-420/50/3 380-420/50/3
Refrigerant R290 R290 R290 R290 R290 R290
Max. heating capacity (1) kW 9 12 15 18 15 18
COP (1) 4.41 3.9 4.45 4.46 4.41 4.46
Heating capacity min./max. (1) kW 4.14 / 9.00 4.35 / 12.00 6.90 / 15.00 8.28 / 18.00 6.90 / 15.00 8.28 / 18.00
Heating input power min./max. (1) W 782 / 2041 885 / 3073 1547 / 4036 1304 / 3401 1547 / 4036
COP min./max. (1) 4.41 / 5.29 3.90 / 4.92 4.45 / 5.34 4.64 / 5.35 4.41 / 5.29 4.46 / 5.35
Max. heating capacity (2) kW 8.6 11.6 14.4 17.3 14.4 17.3
COP (2) 3.53 3.28 3.56 3.57 3.53 3.57
Heating capacity min./max. (2) kW 3.97 / 8.64 4.00 / 11.20 6.62 / 14.40 7.95 / 17.28 6.62 / 14.40 7.95 / 17.28
Heating input power min./max. (2) W 988 / 2449 1071 / 3415 1632 / 4045 1954 / 4843 1647 / 4082 1954 / 4843
COP min./max. (2) 3.53 / 4.02 3.28 / 3.74 3.56 / 4.06 3.57 / 4.07 3.53 / 4.02 3.57 / 4.07
Max. cooling capacity (3) kW 8.2 10.0 13.7 16.4 13.7 16.4
EER (3) 3.42 3.40 3.45 3.46 3.42 3.46
Cooling capacity min./max. (3) kW 3.78 / 8.21 3.81 / 10.00 6.29 / 13.68 7.55 / 16.42 6.29 / 13.68 7.55 / 16.42
Cooling input power min./max. (3) W 958 / 2398 1003 / 2941 1582 / 3962 1894 / 4743 1597 / 3997 1894 / 4743
EER min./max. (3) 3.42 / 3.94 3.40 / 3.80 3.45 / 3.98 3.46 / 3.99 3.42 / 3.94 3.46 / 3.99
Max. cooling capacity (4) kW 5.8 7.2 9.6 11.6 9.6 11.6
EER (4) 2.74 2.62 2.76 2.77 2.74 2.77
Cooling capacity min./max. (4) kW 2.66 / 5.79 3.58 / 7.20 4.44 / 9.65 5.33 / 11.58 4.49 / 9.65 5.33 / 11.58
Cooling input power min./max. (4) W 768 / 2114 1213 / 2748 1268 / 3492 1518 / 4181 1280 / 3524 1518 / 4181
EER min./max. (4) 2.74 / 3.47 2.62 / 2.95 2.76 / 3.50 2.77 / 3.51 2.74 / 3.47 2.77 / 3.51
Rated load kW 3.06 5.00 5.06 6.05 5.1 6.05
Max. input power A 14.65 23.92 24.19 28.97 10.77 12.78
Power cable cross-section mm² 4 6 6 6 4 4
Fuse A 25A 32A 40A 40A 20A 20A
Noise level (1m) dB(A) 46 44 46 46 46 47
Noise level dB(A) 60 58 60 60 60 61
CO₂ equivalent tona 2.64 3.30 3.96 4.62 3.96 4.62
ErP Level (35°C) A+++ A+++ A+++ A+++ A+++ A+++
Net dimensions (LxWxH) mm 1110*475*810 1110*475*960 1110*475*1355 1110*475*1355 1110*475*1355 1110*475*1355
Net packaging dimensions (LxWxH) mm 1165*490*960 1165*490*1100 1165*490*1520 1165*490*1520 1165*490*1520 1165*490*1520
Net weight kg 88 117 124 124 124 124
Gross weight kg 105 133 150 150 150 150
Swipe

Notes:

Sheet metal type: Weather-resistant PP + galvanized steel + ASA

(1) Heating conditions: water inlet/outlet temperature: 30°C/35°C, Ambient temperature: DB 7°C/WB 6°C
(2) Heating conditions: water inlet/outlet temperature: 40°C/45°C, Ambient temperature: DB 7°C/WB 6°C
(3) Cooling conditions: water inlet/outlet temperature: 23°C/18°C, Ambient temperature: DB 35°C/WB 24°C
(4) Cooling conditions: water inlet/outlet temperature: 12°C/7°C, Ambient temperature: DB 35°C/WB 24°C

Downloads

Technical documentation, certificates and user manuals

Our products

Complete solutions for a comfortable home in all seasons. From efficient boilers to modern air conditioners.